J Cardiovasc Dev Dis ; 10(9)2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37754833

RESUMO

OBJECTIVE: This study aims to evaluate image quality in patients with heart rates above or equal to 70 beats per minute (bpm), performed on a 16 cm scanner (256-slice General Electric Revolution) in comparison to a CT scanner with only 4 cm of coverage (64 slice Volume CT). BACKGROUND: Recent advancements in image acquisition, such as whole-heart coverage in a single rotation and post-processing methods in coronary computed tomographic angiography (CCTA), include motion-correction algorithms, such as SnapShot Freeze (SSF), which improve temporal resolution and allow for the assessment of coronary artery disease (CAD) with lower motion scores and better image qualities. Studies from the comprehensive evaluation of high temporal- and spatial-resolution cardiac CT using a wide coverage system (CONVERGE) registry (a multicenter registry at four centers) have shown the 16 cm CT scanner having a better image quality in comparison to the 4 cm scanner. However, these studies failed to include patients with undesirable or high heart rates due to well-documented poor image acquisition on prior generations of CCTA scanners. METHODS: A prospective, observational, multicenter cohort study comparing image quality, quantitively and qualitatively, on scans performed on a 16 cm CCTA in comparison to a cohort of images captured on a 4 cm CCTA at four centers. Participants were recruited based on broad inclusion criteria, and each patient in the 16 cm CCTA arm of the study received a CCTA scan using a 256-slice, whole-heart, single-beat scanner. These patients were then matched by age, gender, and heart rate to patients who underwent CCTA scans on a 4 cm CT scanner. Image quality was graded based on the signal-to-noise ratio, contrast-to-noise ratio, and on a Likert scale of 0-4: 0, very poor-4, excellent. RESULTS: 104 patients were evaluated for this study. The mean heart rate was 75 ± 7 in the 4 cm scanner and 75 ± 7 in the 16 cm one (p = 0.426). The signal-to-noise and contrast-to-noise ratios were higher in the 16 cm scanner (p = 0.0001). In addition, more scans were evaluated as having an excellent quality on the 16 cm scanner than on the 4 cm scanner (p < 0.0001) based on a 4-point Likert scale. CONCLUSIONS: The 16 cm scanner has a superior image quality for fast heart rates compared to the 4 cm scanner. This study shows that there is a significantly higher frequency of excellent and good studies showing better contrast-to-noise and signal-to-noise ratios with the 16 cm scanner compared to the 4 cm scanner.

2.
Br J Radiol ; 96(1151): 20220992, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37486625

RESUMO

OBJECTIVES: Compare accuracy of vertebral Hounsfield Unit (VHU) attenuation and FRAX and Garvan Fracture Risk Calculators in identifying low bone mineral density (BMD) and prevalent vertebral compression fractures (VF) in lung cancer screening (LCS) participants. METHODS: Baseline CT scans from a single site of the International Lung Screen Trial were analysed. BMD was measured using VHU (of the most caudally imaged vertebra) and quantitative CT (QCT) (low BMD defined as <110 HU and <120 mg/cm3, respectively). Prevalent VF were classified semi-quantitatively. 10-year FRAX and Garvan fracture risks were calculated using dual energy X-ray absorptiometry (DXA) femoral neck T-score where available. Discrimination was assessed by area under receiver-operating characteristic curves (AUC). RESULTS: 535 LCS participants were included; 41% had low VHU-BMD, 56% had low QCT-BMD and 10% had ≥1 VF with ≥25% vertebral height loss. VHU demonstrated 94% specificity and 70% sensitivity in identifying low QCT-BMD. VHU was superior to fracture risk tools in discriminating low QCT-BMD (AUC: VHU 0.94 vs FRAX 0.67, Garvan 0.64 [p < 0.05]). In 64 participants with recent DXA scans, VHU was superior to FRAXT-score and GarvanT-score in discriminating low QCT-BMD (AUC: VHU 0.99, FRAXT-score 0.71, GarvanT-score 0.71 [p < 0.05]). VHU was non-inferior to FRAXT-score and GarvanT-score in discriminating VF (AUC: VHU 0.65, FRAXT-score 0.53, GarvanT-score 0.61). CONCLUSIONS: VHU outperforms clinical risk calculators in detecting low BMD and discriminates prevalent VF equally well as risk calculators with T-scores, yet is significantly simpler to perform. ADVANCES IN KNOWLEDGE: VHU measurement could aid osteoporosis assessment in high-risk smokers undergoing LCS.


Assuntos
Fraturas por Compressão , Neoplasias Pulmonares , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Fraturas por Osteoporose/diagnóstico por imagem , Densidade Óssea , Detecção Precoce de Câncer , Fraturas da Coluna Vertebral/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Coluna Vertebral , Absorciometria de Fóton/métodos , Tomografia Computadorizada por Raios X
3.
Tex Heart Inst J ; 49(2)2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35244722

RESUMO

Computed tomographic coronary artery calcium scanning enables cardiovascular risk stratification; however, exposing patients to high radiation levels is an ongoing concern. New-generation computed tomographic systems use lower radiation doses than older systems do. To quantify comparative doses of radiation exposure, we prospectively acquired images from 220 patients with use of a 64-slice GE LightSpeed VCT scanner (control group, n=110) and a 256-slice GE Revolution scanner (study group, n=110). The groups were matched for age, sex, and body mass index; statistical analysis included t tests and linear regression. The mean dose-length product was 21% lower in the study group than in the control group (60.2 ± 27 vs 75.9 ± 22.6 mGy·cm; P <0.001) and also in each body mass index subgroup. Similarly, the mean effective radiation dose was 21% lower in the study group (0.84 ± 0.38 vs 1.06 ± 0.32 mSv) and lower in each weight subgroup. After adjustment for sex, women in the study group had a lower dose-length product (50.4 ± 23.4 vs 64.7 ± 27.6 mGy·cm) than men did and received a lower effective dose (0.7 ± 0.32 vs 0.9 ± 0.38 mSv) (P=0.009). As body mass index and waist circumference increased, so did doses for both scanners. Our study group was exposed to radiation doses lower than the previously determined standard of 1 mSv, even after adjustment for body mass index and waist circumference. In 256-slice scanning for coronary artery calcium, radiation doses are now similar to those in lung cancer screening and mammography.


Assuntos
Doença da Artéria Coronariana , Neoplasias Pulmonares , Cálcio , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Doses de Radiação
4.
J Cardiovasc Imaging ; 29(1): 88-89, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33511810
5.
J Nucl Med Technol ; 49(1): 65-69, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33219160

RESUMO

We intended to assess the ability of current-generation 256-slice coronary CT angiography (CCTA) to measure left atrial volume (LAV), comparing patients with a high heart rate (HiHR) of at least 70 bpm and patients with heart rate variability such as atrial fibrillation (AFib). Methods: Using the prospective Converge Registry of patients undergoing 256-detector CCTA on a Revolution scanner, we enrolled 121 HiHR patients (74 men; mean age, 62.7 ± 12.5 y) and 102 AFib patients (72 men; mean age, 60.5 ± 11.0 y) after obtaining informed consent. Quantitative data analysis of LAV was performed using automated methods, and end-systolic phases were chosen for measurements from CCTA. A Student t test, Wilcoxon rank-sum test, or χ2 test assessed baseline parameters. Univariate and multivariate linear regression analysis was used to assess LAV and LAV index (LAVI) while adjusting potentially confounding variables. Results: Mean LAV was significantly higher in AFib subjects (148.6 ± 57.2 mL) than in HiHR subjects (102.1 ± 36.5 mL) (P < 0.0001). Similarly, mean LAVI was significantly higher in AFib subjects (72.4 ± 28.1 mL/m2) than in HiHR subjects (51.5 ± 19.0 mL/m2) (P < 0.0001). After adjusting for age, body mass index, sex, diabetes, hypertension, hyperlipidemia, and smoking, subjects with AFib had, on average, LAV measures higher by 41.2 ± 6.7 mL and LAVI values higher by 23.1 ± 3.4 mL/m2 (P < 0.0001). Conclusion: Misalignment and motion artifacts in CCTA images affect diagnostic CT performance, especially in patients with elevated heart rates or profound arrhythmia. However, the new-generation Revolution CCTA provides detailed information on left-atrium-complex morphology and function, in addition to coronary anatomy, in HiHR and AFib patients without additional radiation, scanning, or contrast requirements.


Assuntos
Angiografia por Tomografia Computadorizada , Átrios do Coração , Idoso , Átrios do Coração/diagnóstico por imagem , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Tecnologia
6.
J Med Radiat Sci ; 67(1): 25-33, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31693313

RESUMO

INTRODUCTION: Coronary CT Angiography (CCTA) is a rapidly increasing technique for coronary imaging; however, it exposes patients to ionising radiation. We examined the impact of dose reduction techniques using ECG-triggering, kVp/mAs reduction and high-pitch modes on radiation exposure in a large Australian tertiary CCTA service. METHODS: Data on acquisition modes and dose exposure were prospectively collected on all CCTA scans from November 2009 to March 2014 at an Australian tertiary care centre. A dose reduction algorithm was developed using published techniques and implemented with education of medical staff, radiographers and referrers. Associations of CCTA acquisition to radiation over time were analysed with multivariate regression. Specificity in positive CCTA was assessed by correlation with invasive coronary angiography. RESULTS: 3333 CCTAs were analysed. Mean radiation dose decreased from 8.4 mSv to 5.3, 4.4, 3.7, 2.9 and 2.8 mSv (P < 0.001) per year. Patient characteristics were unchanged. Dose reduction strategies using ECG-triggering, kVp/mAs reduction accounted for 91% of the decrease. High-pitch scanning reduced dose by an additional 9%. Lower dose was independently related to lower kVp, heart rate, tube current modulation, BMI, prospective triggering and high-pitch mode (P < 0.01). CCTA specificity remained unchanged despite dose reduction. CONCLUSION: Implementation of evidence-based CCTA dose reduction algorithm and staff education programme resulted in a 67% reduction in radiation exposure, while maintaining diagnostic specificity. This approach is widely applicable to clinical practice for the performance of CCTA.


Assuntos
Angiografia Coronária/métodos , Doses de Radiação , Exposição à Radiação , Tomografia Computadorizada por Raios X/métodos , Austrália , Angiografia Coronária/normas , Medicina Baseada em Evidências/métodos , Medicina Baseada em Evidências/normas , Feminino , Humanos , Masculino , Guias de Prática Clínica como Assunto , Centros de Atenção Terciária/normas , Tomografia Computadorizada por Raios X/normas
7.
J Nucl Med Technol ; 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31604891

RESUMO

Intro: Coronary artery disease is the leading cause for morbidity and mortality. Tools have been developed to accurately diagnose and evaluate coronary artery disease. Coronary computed tomographic angiography (CCTA) scans provide detailed imaging along with analysis to in order to deliver precise analysis and prognostic information. We sought to evaluate the radiation doses of the 256 detector CT scanner to a 64 slice scanner across a similar profile of patients. Methods: Consecutive patients were screened, enrolled, and consented for the Converge Registry study, in accordance with the Institutional Review Board (IRB) approved protocol. 110 patients underwent CCTA using the GE Revolution 256 detector CT scanner. We matched patients by age, gender and body mass index (BMI) who underwent 64 slice CT scanning. Results: We compared 110 patients in each group. We found that mean dose length product (DLP, presented also in the tables below in millisieverts (mSv)) was significantly lower in the Revolution 256 detector group compared to the 64 slice control group (p<0.05). The radiation dose was reduced 32% with use of Revolution 256 detector scanner for BMI between 18.5 and 24.9 (DLP = 111.2 vs 76.1; 1.56 vs 1.07 mSv; p<0.05). For each BMI subgroup, there was a significant decrease in dose. Regression analysis found that with the increase in BMI both scanners experienced a significant increase in DLP. Conclusion: We are able to demonstrate that the 256 slice CT scanner is able to provide CCTA scans at significantly lower radiation doses compared to the 64 row scanner at different BMI groups, with all other variables accounted for. Lower radiation exposures along with lower contrast requirements can provide quality imaging with high diagnostic accuracy and less risk to the patient.

9.
Acad Radiol ; 26(11): 1443-1449, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30683612

RESUMO

RATIONALE AND OBJECTIVES: Novel technology in coronary computed tomographic angiography allows assessment of coronary artery disease with high image quality (IQ). There are currently two wide detector "whole heart" coverage scanners available, which avoid misregistration artifacts. However, there are no data directly comparing IQ between the two scanners. The aim of the current study is to investigate if IQ is different between the most scanners of GE and Toshiba broad detector scanners. MATERIALS AND METHODS: Prospective, observational, multicenter international cohort study comparing 236 consecutive patients who underwent coronary computed tomographic angiography using whole-heart scanners; 126 patients on scanner S1 ( Aquilion ONE Vision, Toshiba), and 110 patients on scanner S2 (Revolution CT, GE Healthcare). Hounsfield units were measured using regions of interest in the descending aorta at 6 points (cranial slice, level of the visualized first, second, third, and fourth spines, and the caudal slice). We also compared the coverage length (z-axis) of the full width field of view between a single rotation of the two scanners. RESULTS: Evaluating mean CT attenuation values Hounsfield units through the scan range, are progressively reduced across the descending aorta in the S1 group, resulting in the larger difference of contrast brightness between the cranial and caudal slices compared to the S2 group (absolute difference: S2 13.0 ± 4.4 vs S1 141.9 ± 16.4, p < 0.0001; Percent difference: 19.3 ± 2.1 vs -3.4 ± 1.2, <0.0001). The standard deviation (SD) is similar at the cranial slice between the two scanners, however, the S1 group demonstrated higher SD-differential from cranial to caudal than S2 group. Median radiation exposure was significantly lower for the S2 scanner 1.50 ± 0.75 mSv vs the S1 system 1.9 mSv (IQR 1.7-2.7 mSv) (p = 0.01). Z-axis coverage was larger for the S2 scanner 152.5 mm (244 slices × 0.625 mm/slice) than 133 mm for S1 (266 slices × 0.5 mm/slice). CONCLUSION: Although both "volume" scanners cover the whole heart z-axis with one beat, scans using the S1 scanner have a larger variability in attenuation values throughout the scan range, resulting in 20% increase in nonuniformity from cranial to caudal slice. Additionally, SD variation across the field of view, a metric of noise, is larger when using the S1 scanner vs the S2 scanner. These results indicate that the GE Revolution CT has more uniform contrast enhancement and more coverage, lower radiation and lower image noise compared to the Toshiba Aquilion ONE Vision system.


Assuntos
Artefatos , Angiografia por Tomografia Computadorizada/instrumentação , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Exposição à Radiação/prevenção & controle , Sistema de Registros , Tomógrafos Computadorizados , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
10.
J Clin Med Res ; 10(10): 781-785, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30214650

RESUMO

Pulmonary artery pseudoaneurysm is a dangerous pathology often missed as a differential and on imaging. With a 50% mortality rate early detection and intervention are critical to patient outcome, rendering diagnosis based on clinical grounds to be of paramount importance. A high index of suspicion should be placed on patients presenting with unprovoked hemoptysis, hemorrhage or hemothorax. Knowledge of the common causes of pulmonary artery pseudoaneurysms is also important; however, it is integral to note spontaneous occurrences in patients with no known risk factors. Herein, we report a case of an unprovoked pulmonary artery pseudoaneurysm in a 72-year-old male with no known risk factors or causes for the pathology. Additionally, we review the pathophysiology behind the potential association of polyarthritic gout as a cause of pulmonary artery pseudoaneurysms. To the best of our knowledge this is the first reported link between the two diseases, providing grounds to widen literature and increase diagnoses of pulmonary artery pseudoaneurysms.

11.
Int J Cardiol Heart Vasc ; 20: 46-49, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30148201

RESUMO

BACKGROUND: It was hypothesized that the accuracy of coronary CT angiography would be affected by case volume of the referring sites. METHODS: The positive predictive value (PPV) of CTCA performed at a tertiary hospital specialising in cardiothoracic medicine and services with lower case-volumes were calculated. The tertiary hospital used as the high case-volume reference centre was The Prince Charles Hospital, which performed >1500 CTCA scans per annum over the study period. The low case-volume services used in the study were suburban radiology services, each with <500 cases per year. The PPV of positive CTCA at the reference site was compared to the pooled PPV of all other sites as a combined cohort, using invasive angiography as the reference standard. 512 scans were included, n = 199 subjects in the reference centre cohort, and n = 311 subjects in the pooled community radiology practice cohort. RESULTS: The positive predictive value (PPV) of the high case-volume group (n = 199) was 0.7538. The PPV of the pooled low case-volume services (n = 589) was 0.7331, p = 0.604, with no statistically significant difference in positive predictive values. CONCLUSIONS: There was no significant difference in PPV between the two groups. This suggests that high-volume and lower-volume sites both have high PPV in Australia, above the published pooled PPV of four large prospective diagnostic accuracy studies (Miller et al., 2008; Budoff et al., 2008; Meijboom et al., 2008; Achenbach, 2007).

12.
J Thorac Imaging ; 32(6): W67-W68, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28914745

RESUMO

Chest digital tomosynthesis (DT) has potential advantages compared to computed tomography (CT) such as radiation dose reduction. However, the role of DT in pulmonary nodule management remains investigative. We compared DT against CT for pulmonary nodule detection and size measurement. A clinical population comprising 54 nodules from 30 patients and a screening population comprising 42 nodules from 52 patients were included. Scans were independently read by two radiologists. Agreement in nodule measurements between readers and between modalities was assessed by Bland-Altman analysis using a 95% level of significance. The DT true positive fraction for the two readers was 0.44 and 0.39 in the clinical population, and 0.10 and 0.05 in the screening population. No significant inter-modality bias was observed between DT and CT measurements of nodule size, but the range of variation between modalities was approximately 30%. Inter-reader DT measurements also showed no significant bias, with a range of variation of approximately 15%. We conclude that DT has poor nodule detection sensitivity compared to CT. However, DT showed good measurement reproducibility and may be useful for monitoring growth of existing pulmonary nodules.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Radiografia Torácica/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Radiografia Torácica/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/estatística & dados numéricos